Flint-walling Pressure Booster Pumps Instructions Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Čerpadla Flint-walling Pressure Booster Pumps Instructions. Flint & Walling Pressure Booster Pumps Instructions User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 15
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
1
Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755
flintandwalling.com
Description
Pressure booster pumps increase water pressure from city mains or private water
systems. Applications include providing high water pressure for washing buildings, dairy
walls or floors, hog parlors, poultry houses, rinsing or spray cooling equipment, lawn
sprinkling and insecticide spraying.
Single-phase models are equipped with a capacitor start, thermal protected motor.
Three-phase models require separate overload protection.
Unpacking
When unpacking the unit, inspect
carefully for any damage that may
have occurred during transit.
NOTE: Use pump with clear water
only.
132934 C
Pressure Booster Pumps
Operating Instructions & Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop-
erty damage! Retain instructions for future reference.
IL0391B
3.88
3.25 "C"
"F"
3.75
9.75
1-1/2 & 2HP 1Ø TEFC
ALL 3HP 1Ø
9.00
(MODELS WITH HANDLES)
6.50
7.15
4.88
TEFC ONLY
5.28
2 & 3HP
1Ø TEFC ONLY
1.44
"H" INLET
"J" DISCHARGE
Figure 1
Pump Dimensions 60 Hz Chart A
HP GPM Stage “C”
F
H J
F&W
TEFC
1 Phase 3 Phase
1/3 5 8 10.19 19.81 - - .75 .75
1/3* 5 8 10.19 20.06 22.04 - .75 .75
1/2 5 12 13.38 23.25 23.23 24.10 .75 .75
1/2* 5 14 14.97 25.34 26.82 25.69 .75 .75
3/4 5 16 16.54 26.91 28.77 27.51 .75 .75
3/4 7 12 13.38 23.75 25.61 24.35 .75 .75
3/4* 7 14 14.97 25.84 27.20 25.94 .75 .75
1 10 14 16.31 27.18 29.16 28.02 .75 .75
1-1/2 10 16 18.13 29.62 31.48 30.07 .75 .75
1* 10 20 21.69 33.18 34.54 33.40 .75 .75
1* 10 22 23.50 34.99 36.35 35.21 .75 .75
1* 10 23 24.38 35.87 37.73 36.09 .75 .75
2 19 14 17.89 29.88 32.12 30.87 .75 .75
1-1/2* 19 20 24.06 36.05 37.41 36.00 .75 .75
2* 19 22 26.13 38.12 40.36 39.11 .75 .75
2 27 11 15.38 27.37 29.61 28.36 1.00 1.00
3 27 14 18.50 30.49 33.85 33.35 1.00 1.00
2* 27 17 21.59 33.58 35.82 34.57 1.00 1.00
3 27 17 21.59 33.74 - - 1.00 1.00
2 35 6 13.94 25.93 28.17 26.92 1.00 1.00
3 35 8 17.13 29.12 32.48 31.98 1.00 1.00
1-1/2* 35 8 17.13 29.12 30.48 29.07 1.00 1.00
3* 35 14 26.86 38.85 42.21 41.71 1.00 1.00
Zobrazit stránku 0
1 2 3 4 5 6 ... 14 15

Shrnutí obsahu

Strany 1 - Pressure Booster Pumps

1Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comDescriptionPressure booster pumps increase

Strany 2 - 60Hz Models

10Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comOperation (Continued)START - UP PROCEDURE

Strany 3

11Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comMaintenance (Continued) IMPORTANT: Do no

Strany 4 - Pre-Installation

12Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comTroubleshooting ChartSymptom Possible Cau

Strany 5

13Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comBooster Pump Parts DrawingFigure 20 - Car

Strany 6 - Installation (Continued)

14Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comFORM NO. FW00450813SUPERSEDES 0208IL05659

Strany 7

15Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comPRESSURE BOOSTER PUMP REPAIR PARTS(For Pr

Strany 8

2Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comSingle Phase Motor Data 60HZ

Strany 9 - Operation

3Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comThree Phase Motor Data

Strany 10 - Maintenance

4Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comGeneral Safety InformationCarefully read a

Strany 11 - Maintenance (Continued)

5Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comIL1014Mount pump in correct position or pu

Strany 12 - Troubleshooting Chart

6Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comInstallation (Continued)5. A pressure gau

Strany 13 - Internal Parts Detail

7Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comInstallation (Continued) Proper rotation o

Strany 14 - Replacement Motors

8Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comInstallation (Continued)IL1229654321789654

Strany 15 - 60 HZ MODELS

9Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comInstallation (Continued)5. Specific Wirin

Komentáře k této Příručce

Žádné komentáře